download4all

You can download the OMS Specifikationen and other information here:


KNX and OMS position paper

The Executive Board of the OMS-Group has released the “KNX and OMS position paper”. The paper describes the technology base for the exchange of data between smart metering and home and building automation.

Brochure of die OMS-Group e.V. 2016

Secure and Interoperable Communication of Metering Data with M-Bus: Open Metering System (OMS). The Only Open Standard for Smart Metering Across all Energy Types. OMS-Group 2016

The OMS-Group e.V. at Wikipedia


Prof. Dr.-Ing. Bert Oschatz et al., Kurzgutachten. Beitrag intelligenter Messsysteme für Strom, Gas und Wärme zur CO2-Minderung, Dresden 2015

Das hohe Potential intelligenter Messysteme für Strom, Gas und Wärme zur Einergieinsparung und CO2 Minderung wird durch ein aktuelles Kurzgutachten des Institutes für Technische Gebäudeausrüstung Dresden – ITG eindrucksvoll bestätigt. Aufttraggeber dieses Kurzgutachtenssind unter Führung der figawa auch grzi e.V., OMS-Group e.V. und vddw e.V. . Das Gutachten wird derzeit unter anderem in die Beratungen über das geplante Bundesgesetz zu Digitalisierung der Energiewende eingebracht. Es steht hier zum Download zur Verfügung.

Standpunkt der Verbände OMS-Group e.V., FIGAWA, GRZI, VDDW und KNX

zur Stellungnahme des Bundesrates zum Entwurf eines Gesetzes zur Digitalisierung der Energiewende

OMS specifications and conformity 

The OMS specification currently consists 3 parts:

Volume 1: General - Open Metering System Overview
Volume 2: Primary Communication - communication between counter or actuator and the gateway
Volume 3: Tertiary communication - communication between the gateway and the network operator (Head End System). The Volume 3 is currently not under development.


The
following table gives an overview of which parts of the OMS specification should be used together and what version of the conformance test to be applied for the detection of the OMS-conformity.

Generation 1

unidirectional radio meter

Status: withdrawn

usage area

no new installation

OMS Specification

OMS Conformance

OMS TestTool

Vol. 1 General Part 1.2.0

not planned

not planned

Vol. 2 Primär Kommunikation 1.0.2

not planned

not planned

Vol. 3 Tertiär Kommunikation 1.0.0

not planned

not planned

Generation 2

Uni- & bidirectional meters with wM-Bus 868 MHz

Status: released, recommended for usage and certification, new development (without BSI for Germany)!

Usage Area

All meters for countries that permit 886 MHz (i.e. CEPT countries like EU and EEA) with exception of electricity meters for German consumers >6 MWh/year

OMS Specification

OMS Conformance

OMS Test Tool for Version 2

Vol. 1 General Part 1.2.0

Version 1.0.1

Version 1.0.3

Vol. 2 Primary Communication 2.0.0

Version 1.0.1

Version 1.0.3

Vol. 3 Tertiary Communication 2.0.0

not planned

not planned

Generation 3

Uni- & bidirectional meters with wM-Bus 868MHz & repeaters with battery

Status: released, recommended for development, usage and certification (without BSI for Germany)

Usage area

Same as Version 2 plus meters using battery powered repeaters

OMS Specification

OMS Conformance

OMS Test Tool for Generation 3

Vol. 1 General Part 1.4.0

Version 3.0.0

Version 3.0

Appendix Glossary 1.0.1

no testing

no testing

Vol. 2 Primary communications 3.0.1

Version 3.0.0

Version 3.0

Technical Report 01 Issue 1.1.0

no testing

no testing

Vol. 3 Tertiary communicatios 2.0.0 - not up to date

postponed

postponed

Generation 4

Uni- & bidirectional meters and gateways for wM-Bus & (wired M-Bus = currently under development)

Status: partly released, recommended for development, especially for German market!

Usage Area

All meters & gateways for countries permitting 868 MHz (i.e. CEPT countries as the EU & EEA) including all German electricity meter (also with BSI requirement). Battery powerded repeaters.

OMS Specification

OMS Conformance

OMS TestTool for version 4

Vol.1 General Part 2.0.1

Version 4.0

Order form for version 4

Vol. 1 Appenix Glossar 1.0.1 - Release A

Vol. 1 Appendix Glossary 2.0.1 - Release B

no testing

no testing

Vol. 2 Primary communication v4.0.2

planned

Order form for version 4

Vol. 2 Annex A: OBIS-Code List - Release A

planned

no testing

Vol. 2 Annex B: OMS Data point list - Release A

planned

no testing

Vol. 2 Annex N: OMS Datagram-examples - Release A

planned

no testing

Vol. 2 Annex O: Alternativ Physical Layers for wM-Bus – Release A

planned

no testing

Vol. 2 Primary communication v4.1.2

planned

Order form for version 4

Vol.2 Annex A: OBIS-Code list - Release B

planned

no testing

Vol. 2 Annex B: OMS Data point list - Release B

planned

no testing

Vol. 2 Annex E: National special features

planned

no testing

Vol. 2 Annex F: Transport Layer Security for M-Bus

planned

no testing

Vol. 2 Annex N: OMS Datagram-examples - Release B

planned

no testing

Vol. 2 Annex O: Alternative Physical Layers for wM-Bus – Release A

planned

no testing

ERRATA List OMS-Spec. Issue 4.0.1.

no testing

no testing

Legend: Italic = presently not available

Generation 1

 This version is not supported anymore.

Generation 2

OMS-Spezifikation

OMS-conformity

Generation 3

This generation supports repeaters with batteries. Together with the extensions specified in MS-Report OMS-TR-01. This version provides conformity with BSI-TR03109.

 

OMS-Spezifikation

OMS-conformity

Generation 4

This specification is being prepared to meet the requirements of BSI TR03109 V2. The recommendations of the OMS-report OMS-TR-01 have been implemented in this specification.

OMS-Spezifikation:

Volume 1, General Part, Issue 2.0.1

External annexs volume 1:

Volume 2, Primary Communication, Issue 4.0.2

External annexes volume 2:

Volume 2, Primary Communication, Issue 4.1.2

External annexes volume 2:

OMS-Konformität

Link to test and test tool

OMS-Technical Reports

The articles of association of the OMS-Group e.V.

Die Vereinszeichensatzung der OMS-Group e.V.

Membership Application Form OMS-Group e.V.

OMS Smart Metering: Certification Made Easy

OMS-Group is providing a new testing tool that enables the certification of smart meter communication. The testing tool is used by the certification authority to assure that devices conform with the OMS specifications. It can...[more]


Displaying results ###SPAN_BEGIN###%s to %s out of ###SPAN_BEGIN###%s
<< First < Previous 1-1 2-2 3-3 4-4 5-5 6-6 7-7 Next > Last >>
14.03.2017

ISH

Frankfurt, Germany[more]


16.03.2017

Intersec Forum 2017

Frankfurt am Main, Germany[more]


Displaying results ###SPAN_BEGIN###%s to %s out of ###SPAN_BEGIN###%s
<< First < Previous 1-2 3-4 5-6 7-8 9-9 Next > Last >>